Advertisement

SECTIONAL-800PRO-CE
SECTIONAL-1000PRO-CE
Operator
Installation and Operation Manual
Actual versions::
Soft - v 1.7; PCB - v 1.3
© DoorHan, 03.2019
2
3
5
6
9
10
17
17
18
19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SECTIONAL-800PRO-CE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DoorHan SECTIONAL-800PRO-CE

  • Page 1: Table Of Contents

    General Information Safety Instructions Operator Unit Operator Installation Electrical Connections Operator Programming Manual Opening Maintenance Troubleshooting Appendix SECTIONAL-800PRO-CE SECTIONAL-1000PRO-CE Operator Installation and Operation Manual Actual versions:: Soft — v 1.7; PCB — v 1.3 © DoorHan, 03.2019...
  • Page 2: General Information

    20% larger. 1.2. OPERATOR PACKAGE When you receive your Sectional-800PRO-CE / 1000PRO-CE operator, unpack it and check that the operator is not damaged. If any damages are found, contact the operator supplier. The operator components included in the standard package are showed below.
  • Page 3: Safety Instructions

    • You should follow all the recommendations of the given manual, as incorrect equipment installation can lead to serious damages. • The Sectional-800PRO-CE / 1000PRO-CE operator is designed for automation of residential sectional doors. It should be used only for the purpose intended; any other use is prohibited.
  • Page 4 • You should use additional DoorHan accessories, since the accessories of third party manufacturers can damage the automatic system. • DoorHan is not liable for unstable work of the automatic system, if you use safety devices and accessories, produced by other manufacturers without securing approval of DoorHan.
  • Page 5: Operator Unit

    Have a qualified technician lay the cables 230 V AC. The cables must be laid in protective corrugated tubes. In case of supply cable damage, use the suitable type of the cable. Cables needed for installation of Sectional-800PRO-CE / 1000PRO-CE operator and accessories (if available): Cable 2 × 0,5 mm •...
  • Page 6: Operator Installation

    OPERATOR INSTALLATION 4. OPERATOR INSTALLATION 4.1. TOOLS 1. Set of spanners 4. Set of drills for concrete 7. Electric drill 2. Set of slotted and cross screwdrivers 5. Pliers 8. Tape measure (folding rule) 3. Set of drills for metal 6.
  • Page 7 OPERATOR INSTALLATION 4.4. TRACK INSTALLATION The height of operator installation depends on maximum lift of upper edge of the door leaf. After preliminary assembly (see p. 4.3) you can start to install the track: 1. If it is necesssary to shorten the track, do it as described in the Appendix. 2.
  • Page 8 OPERATOR INSTALLATION FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 FIG. 8 α 4.5. MECHANICAL STOPPER INSTALATION FIG. 1 FIG. 2   FIG. 3 FIG. 4...
  • Page 9: Electrical Connections

    ELECTRICAL CONNECTIONS FIG. 5 FIG. 6 30° < α < 60° 5. ELECTRICAL CONNECTIONS 5.1. CONTROL BLOCK SPECIFICATIONS Parameters Value Power supply 180-240 V, 50 Hz Power supply of accessories 24 V DC Maximum current of accessories 200 mA Operating temperature range -20…+55°C Radio control frequency 433.92 MHz...
  • Page 10: Operator Programming

    OPERATOR PROGRAMMING For easy connection of accessories, the operator is equipped with a removable terminal located under the plug (see fig. 2), it allows you to make all the necessary connections without disassembling the operator housing. FIG. 2 6. OPERATOR PROGRAMMING 6.1.
  • Page 11 OPERATOR PROGRAMMING 6.3. BASIC PROGRAMMING Menu Function description Default Door upper position – Door lower position – Automatic force adjustment Partial opening of the door (ventilation): «Y» – on, «n» – off Safety devices: «Y» – on, «n» – off Reverse of the carriage when the door is closed Automatic door closing: «0»...
  • Page 12 OPERATOR PROGRAMMING 4. Ventilation (Partial opening) Record remote button to control the partial opening of the door. Pressing «+» and «-», set the value of the function «Y». Confirm your selection by pressing the «P» button. After pressing the «P» button, the operator automatically switches to the recording mode of the control button. Press «+»...
  • Page 13 OPERATOR PROGRAMMING 9. Software version Press «+» «8» will light, press «Р» The first digit is displaied The second digit is displaied When you enter the ninth menu item, two numbers are displayed sequentially. After the numbers are displayed, the program returns to the main menu.
  • Page 14 OPERATOR PROGRAMMING 2. Absolute cycle counter Press «+» «2» will light, press «Р» The first digit is displaied The second digit is displaied After you enter the menu item «2», 4 digits will be displayed in turn: the first digit — tens of thousands, the second digit — thousands, the third digit —...
  • Page 15 OPERATOR PROGRAMMING 7. Type of reference point Press «+» «7» will light, press «Р» Pressing «+» or «-» choose the function value: «1» – microswitch, Press «P» to save the settings «2» – stopper NOTE: When switching to another function, you must repeat steps 1-3 of the basic programming. 8.
  • Page 16 5. Select the button on the new remote control, using which you will later operate the unit, and press it twice. A short beep will sound. NOTE: All four control buttons can be programmed for the operator. 5. Marking of the DOORHAN remote controls’ buttons...
  • Page 17: Manual Opening

    MANUAL OPENING 7. MANUAL OPENING Opening by means of integrated carriage releasing device FIG. 1. Emergency release FIG. 2. Manual contol FIG. 3. Automatic control Locked position Pull the cord down and Unlocked position Unlocked position Pull the cord down and Locked position move the rod to the move the rod to the...
  • Page 18: Troubleshooting

    TROUBLESHOOTING that can significantly affect the service life and quality of work of the whole entrance group or its component parts (including automation). 9. TROUBLESHOOTING Symptom Possible reason Possible solution Operator does not run No power supply / Blown fuse Turn power on / Change the fuse Remote control isn’t recorded in the receiver Remote control does not run...
  • Page 19: Appendix

    APPENDIX APPENDIX To cut the track: 1. Unpack the track and check it. Make sure it is not damaged. If you have found any damage, contact your vendor. 2. Disassemble the chain tension mechanism (fig. 1). 3. Remove the chain with the carriage mechanism (fig. 2). 4.
  • Page 20 For acquisition, distribution and maintenance please contact your local DoorHan dealer or the central office at: Kadan, 43201, Czech Republic Telephone: +420 474 319 111 E-mail: europe@doorhan.com...