  • Page 1 InstallatIon and operatIng manual seCtIonal-750/1200/Fast-750...
  • Page 2: Table Of Contents

    Table of conTenTs Intended use ............................3 KIt ComposItIon ............................3 general saFetY InstruCtIons to FoloW at InstaltIons ..............3 tols ................................4 saFetY at InstalatIon ..........................4 speCIFICatIons ............................5 dimensions ............................6 description ............................6 asem BlY ..............................6 pre-check ............................. 6 Connection of operator to guide ......................
  • Page 3: Intended Use

    InTenDeD Use This manual is for operators DOORHAN SECTIONAL KIT COMPOSITION automatic system seCtIonal is intended for use with residential № name Quantity balanced gate (moderate use). operator the system consists of an electromechanical motor-reducer, an electronic control unit and a light lamp, located in common case. this radio control button system is secured to ceiling and opens automatic gate by motion of chain.
  • Page 4: Tols

    doorHan.
  • Page 5: Specifications

    SPECIFICATIONS Model Sectional-750 Sectional-1200 Supply voltage range, V 180-240 Current frequency, Hz Motor voltage (V dc) Maximum consumed power (W) Force (Н) max. 1200 Duty type short-time duty - 5 minutes Light lamp (V ~/W) 230 / 25 max.
  • Page 6: Dimensions

    DescrIPTIon DESCRIPTION Case cover panel cover Key panel Control board motor-reducer transformer light lamp microswitch adapter protection cover ASSEMBLY Pre-check design of the gate shall meet the requirements of automation. In particular, check correspondence of the aperture dimensions with the dimensions, specified in the manual, as well as aperture material rigidity.
  • Page 7: Connection Of Operator To Guide

    INSTALLATION Have only the certified personnel, which was trained at the authorized centres doorHan, carry out installation of the item. • to ensure maximum safety, the operator shall be installed only, when the gate is closed. •...
  • Page 8: External Release (Optional)

    ManUal releasIng aUToMaTIc sysTeM MANUAL RELEASING AUTOMATIC SYSTEM In the case of power failure (1). When the door is in closed position: pull down on the rope and dis-engage the clutch, this will allow the door to be lifted with easily. (2). When the door is in the open position: pull down on the rope once, this will allow the door to move downward to the closed position.
  • Page 9: Wiring

    WIrIng WIRING Important: Before beginning work with the operator (connection, maintenance), do always disconnect supply voltage. Button control Main panel Reciever 433 MHz Photocell Door +12V Motor 230 V (L/N) note: Basic kit does not include photocells. photocells are supplied optionally. type of photocells for use – universal, infra-red with no and nC contacts.
  • Page 10: Programing

    PrograMMIng PROGRAMMING Preparation put the slide in locked state. turn on the power supply, an indicator on the operator will light up and a sound signal will be heard. If the programming is not completed, the settings will not be saved. If there is a mistake in any of the settings, you can turn off the power and restart programming.
  • Page 11: Automatic Closing (Factory Preset: 0 - Function Is Off)

    3 sec press “+” or “�” for changing force level � Automatic adjustment (max force level 20 kg) PrograMMIng If the force level is set too low, the door moving will be affected when the mechanical Press to “p” to save the settings structure of the door is not well�balanced Transmitter Control Button Settings Set in the factory...
  • Page 12: Remote Control Delete

    If the gate requires repairs, contact the authorized centres doorHan. MAINTENANCE maintenance shall be carried out by the personnel, which was trained and certified at the authorized centre doorHan. replacement of fuses shall be performed by the personnel, which is certified to perform electric operations.
  • Page 13: Possible Malfunctions And Trooble Shooting

    PossIble MalfUncTIons anD Trooble sHooTIng POSSIBLE MALFUNCTIONS AND TROOBLE SHOOTING to avoid electrical shock all operations on setting and connection shall be carried out by the qualified and licensed personnel. Malfunction Possible reason Solution operator does not run 1. no power 2.Fuse is damaged 1.
  • Page 14: Note

    noTes I n s t a l l a t I o n a n d o p e r a t I n g m a n u a l s e C t I o n a l - 7 5 0 / 1 2 0 0...
  • Page 15 noTes I n s t a l l a t I o n a n d o p e r a t I n g m a n u a l s e C t I o n a l - 7 5 0 / 1 2 0 0...
  • Page 16 120 Novaya street, Akulovo village, Odintsovo district, Moskow region, 143002 Russia Tel: +7(495)933–2400, 981–1133 E–mail: info@doorhan.ru www.doorhan.com...