DoorHan swing-3000 Installation And Operating Manual

DoorHan swing-3000 Installation And Operating Manual

Hide thumbs Also See for swing-3000:

Advertisement

OperatOr
SWING-3000/5000
Installation and operating manual
© DoorHan, 2013
General InformatIon
safety InstructIons
operator InstallatIon
electrIcal connectIons
extreme posItIons aDjustment
operator proGrammInG
proGrammInG of remote controls
release operatIon
troublesHootInG
2
contents
2
3
5
operator unIt
5
8
10
11
12
12
12
maIntenance
13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the swing-3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DoorHan swing-3000

  • Page 1 General InformatIon safety InstructIons operator unIt operator InstallatIon electrIcal connectIons extreme posItIons aDjustment operator proGrammInG proGrammInG of remote controls release operatIon OperatOr maIntenance troublesHootInG SWING-3000/5000 Installation and operating manual © DoorHan, 2013...
  • Page 2: Table Of Contents

    1. General InformatIon The electromechanical linear operator Swing-3000/5000 is intended for automation of a street double-leaf swinging gate with a load-bearing structure. The body of the operator, which consists of two silumin parts, houses a motor, a reducer and a lead screw.
  • Page 3: Technical Specifications

     Swing-3000/5000 was designed for automation of a street double leaf swinging gate with a load bearing structure. do not  use the operator for other than intended purposes.
  • Page 4: Swing

     doorhan shall not be held liable in case of improper installation of the item and damage arisen during operation. ...
  • Page 5: Operator Unit

    Гайка М8 Operator front bracket rear fork rear bracket release unit lead screw M8×10 M8×50 swing-3000 stroke swing-5000 stroke 4. operator InstallatIon 4.1. tools Set of spanners pliers Set of slotted and cross screwdrivers hacksaw for metal Set of drills for metal...
  • Page 6: Installation Layout

    220-240 V Ac. The cables must be laid in protective corrugated tubes. Avoid contact of cables and moving parts of the door. In case of supply cable damage, use the suitable type of the cable. Cables needed for installation of the swing-3000/5000 operator and accessories (if available): cable 2 × 0.5 mm (photocell transmitter, stepped control button);...
  • Page 7: Inward Gate Opening

    4.3. InWard Gate openInG WarnInG! make sure, that the dimension c does not exceed the value indicated in the table below. Otherwise it is necessary to improve the pole according to the indicated dimension value. swing-3000 Pole opening angle a, mm...
  • Page 8: Outward Gate Opening

    electrIcal connectIons 4.4. outWard Gate openInG (sWInG-5000) position the rear bracket in accordance with the dimensions A and B, listed in the table. Install and fasten the rear bracket to the pole using an additional bracket. Open the gate, measure distance d and fasten the front bracket to the gate leaf. opening angle a, mm B, mm...
  • Page 9 electrIcal connectIons 5.2. Control BloCk termInals power supply connector (J1) ~220–240 V (re, n, l) — connector on the control unit used for connection to supply voltage unit. pe — connection to earth n — power supply (neutral) l — power supply (phase) Connector for electric operators and signal lamp (J7) 1-2-3.
  • Page 10: Extreme Positions Adjustment

    extreme posItIons aDjustment 6. extreme posItIons adJustment 6.1. preparatIon screw casing cover 1. unscrew 2 tapping screws and remove the cover. 2. unscrew 2 tapping screws and remove the lead screw casing. nut m8 lead screw 3. Install the front and back brackets on the operator. 6.2.
  • Page 11: Operator Programming

    operator proGrammInG 7. operator proGrammInG 7.1. BasIC proGrammInG To go into the BASIc prOGrAmmInG mOde, press the key “f”. On the left display you will see the name of the function, which is to be programmed and on the right display you will see current value of this function. The value can be changed by pressing keys “+”...
  • Page 12: Programming Of Remote Controls

    The Swing-3000/5000 automatic system does not require any special servicing.  repairs may be carried out only by a qualified technician trained and certified at an authorized doorhan centre.  Be sure that after completion of installation the installer has shown the user how to release the door in case of emergency ...
  • Page 13: Troubleshooting

    troublesHootInG 11. trouBleshootInG symptom possible reason solution power is off make sure, that the power is on Obstruction at gate’s movement remove the obstruction Operator does not run Bad wiring connection check reliability of electric wiring connection Operator is released engage the operator Operator stops suddenly Thermal protection is active...
  • Page 14 notes...
  • Page 15 notes...
  • Page 16 We very much appreciate that you have chosen the product manufactured by our company and believe that you will be satisfied with its quality. for information on purchasing, distribution and servicing contact doorhan central office at: Kralovsky Vrch 2018, Kadan, 43201, czech republic Telephone: +420 474 319 111 e-mail: europe@doorhan.com...