Meter; Blend Valve - Wayne Vista Series Service

Blending and non-blending suction pumps and remote dispensers
Table of Contents

Advertisement

7.2.4.

Meter

Note:
Before removing the meter, trip the impact valve and shut OFF the submers-
ible pump for the product in question.
1. Remove the four (4) bolts which secure the meter to the meter support.
2. Remove the meter. Note the position of the two (2) "O" rings so that they
3. Reinstall the meter using the previously removed bolts. Take care that the
4. Check operation and inspect for leaks.
7.2.5.

Blend Valve

Note:
Before removing the blend valve, trip the impact valve and shut off the sub-
mersible pump for the products in question.
On some dispenser models, one of the blend valves will be located inside the
side column of the dispenser. Verify the location of the valve by visually
following the linkage from the blend motor to the valve.
1. Disconnect the blend motor to blend valve linkage at the blend valve.
2. Remove the four bolts which secure the valve to the hose outlets.
3. Remove the six bolts which secure the valve to the inlet tubes.
4. Remove the blend valve. Be sure to provide some means of catching the
5. Install the new blend valve using the reverse procedure. Be sure to use
6. Purge all air from the dispenser and check for proper operation.
November 1992
may be replaced in the proper location.
"O" rings remain in their proper positions.
product which is spilled from the dispenser.
new gaskets on the inlet to the valve.
Part No. 917543 Rev. A
69

Advertisement

Table of Contents
loading