Figure 3-2A Duplex Ii Fault Code Displey Format And Definitions; Figure 3-2B. Duplex Ii Fault Code Displey Example - Wayne Vista Series Service

Blending and non-blending suction pumps and remote dispensers
Table of Contents

Advertisement

MAIN SALE DISPLAY
NNN-S
PF-CC.T
FIGURE 3-2A. DUPLEX II FAULT CODE DISPLAY FORMAT AND DEFINITIONS
FIGURE 3-2B. DUPLEX II FAULT CODE DISPLAY EXAMPLE
16
Part No. 917543 Rev. A
NNN = Sequence Number in the range of 000 - 999
S = Side 1 or 2. This is the side on which the code was
detected.
T = Fault Code Status: 1 = Error
CC = Fault Code number in the range of 00 - 99
F = Fault Source. This value identifies the fault source if the fault can be
linked to a particular hydraulic condition. The range is 0 - 7, "H" or "L".
The numeric values indicate positions (0 = none) while the letters
indicate blending feedstocks.
P = Product Source. This is the position that was selected at the time the
fault occurred. The range is 0 - 7, with 0 = no position selected.
MAIN SALE DISPLAY
3 = Service
2 = Hydraulic 4 = Disable
November 1992