Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Wayne Manuals
Dispenser
Vista Series
Service
Flowchart A-19. Unit Resets But Will Not Dispense - Wayne Vista Series Service
Blending and non-blending suction pumps and remote dispensers
Hide thumbs
1
2
3
4
Table Of Contents
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
page
of
166
Go
/
166
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Dispenser resets but
will not dispense
product.
Check the F1 fuse
on the solenoid drive
board. Replace if it is
open.
Check for 110VAC
output from the
solenoid drive
board to the relay(s)
and the solenoid
valve(s).
Is 110VAC
present?
Check for 110VAC
on valve and relay
select wires in the
junction box.
Is 110VAC
present?
Check actuator, or
relay coil for
continuity.
Is the
coil reading
an open circuit?
Replace defective
actuator or relay.
FLOWCHART A-19. UNIT RESETS BUT WILL NOT DISPENSE
November 1992
problem
corrected?
NO
NO
YES
NO
YES
YES
NO
Is the
YES
Replace solenoid
drive board.
Repair or replace the
defective internal
dispenser wiring.
Replace the actuator
coil or the relay.
END
Is the
problem
YES
corrected?
NO
Replace defective
computer.
Part No. 917543 Rev. A
91
Table of
Contents
Previous
Page
Next
Page
1
...
102
103
104
105
Advertisement
Table of Contents
Troubleshooting
TROUBLESHOOTING GUIDE
59
APPENDIX A TROUBLESHOOTING FLOWCHARTS
83
APPENDIX B ELECTRONIC/ELECTRICAL COMPONENT TROUBLESHOOTING
105
APPENDIX D GILBARCO PULSER INTERFACE PCB TROUBLESHOOTING
159
Related Manuals for Wayne Vista Series
Dispenser Wayne Dresser Vista 1 Series Service Manual
Blending and non-blending remote dispensers (150 pages)
Dispenser Wayne 3/VISTA series Service Manual
Blending and non-blending dispensers (83 pages)
Dispenser WAYNE GLOBAL VISTA CNG Instruction Manual
(28 pages)
Dispenser Wayne Ovation Installation & Operation Manual
(88 pages)
Dispenser Wayne Reliance G6101D Installation & Operation Manual
S1 ast mechanical registration fleet dispensers (44 pages)
Related Content for Wayne Vista Series
Dresser Vista 1 Series Figure A-24. Dispenser Resets But Will Not Dispense Product
Wayne Dresser Vista 1 Series
Ovation Setting Unit Prices
Wayne Ovation
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL