Flowchart A-2. 02 Fault Code - Wayne Vista Series Service

Blending and non-blending suction pumps and remote dispensers
Table of Contents

Advertisement

74
Part No. 917543 Rev. A
02 fault code.
Pust to start
option disabled
but switch
detected.
Ensure that the
two wires normally
connected to the
PTS switch are
shorted.
Replace the wiring
which would attach
to the PTS switch.
Is the
problem
corrected?
NO
Replace the lighted
cash credit interface
board.
Is the
problem
corrected?
NO
Replace the
computer.
END

FLOWCHART A-2. 02 FAULT CODE

YES
YES
November 1992

Advertisement

Table of Contents
loading