2.2.
UNIT PRICES/AUTHORIZATION, continued
This exposes the function switch access door; unlock this door and slide it to the left.
The function switches which are located behind the door opened in the previous step
are: the Authorize (Self-Serve/Attend) switch, the Totals pushbutton, the Position
Select pushbutton, and the DCPT power switch (if the dispenser is equipped with
DCPT's).
2.2.1.

Manually Setting Unit Prices

The following procedures need not be used if the dispenser is connected to a
control system. Refer to the operating procedures provided with the control
system for a complete description of unit price setting.
The operating levers must be OFF to set unit prices.
The Position Select pushbutton selects the position for which the unit price is to be
changed. The Price Jog pushbutton changes the price of the position selected.
See also, Tables 2-1, 2-2 and 2-3 for blenders and non-blenders.
The first closure of the Position Select pushbutton selects position "X" unit
price (credit price of Cash/Credit type dispenser) and will blank the Unit Price
displays for the position "Y", "Z", and "AA". The unit price for position "X"
is set as follows:
The first closure of the Price Jog pushbutton causes the least significant digit or
tenths of cents position of the unit price to cycle (see Figure 2-2). The digit will
cycle 0 through 9 until the switch is released. Each successive closure of the Price
Jog pushbutton will select and increment the next most significant digit.
Subsequent Position Select switch closures are defined in Table 2-1, 2-2 and
2-3. The unit price for each position may then be set as described above.
2.2.2.

Authorize Switch

The Authorize switch permits dispenser operation with or without console
control. In the self service position (toggle the switch down), the dispenser
must be authorized by the control system before each use. In the full service
position (toggle the switch up as shown in Figure 2-1), the dispenser may be
operated repeatedly without authorization from a control system.
November 1992
There is an Authorize switch for each fueling point.