82
Vision Series 5 Controller User Manual
Press the Set Origin button to store the location into the preset home origin that was selected on the
origin select screen.
Going back into the preset home origin option will then display the X and Y position that was set. In the
example below, a value of 2 inches on the X and 3 inches on the Y were set for preset home 2.
The value shown for the X and Y position will be shown in the units selected on the Utilities screen.
To reset the origin back to the machine's default location at the upper left corner of the table, select the X
absolute box and enter 0. Then select the Y absolute box and enter 0.
Select Set Origin. The default origin will now be set.
IMPORTANT: When using an origin other than 1, it must be selected in the Vision software. To do this,
select the Engrave menu and then Tool Options. Change the preset home position value to the desired
origin location.
Origins 9 through 14 can be accessed by selecting the right arrow in the lower left side of the screen.
The arrows toggle between origins 1-8 and 9-14.
NOTE: The last two origins on page 2 are reserved for using a rotary device and using the measure
feature.