4. Output (Built-in Relay) Life Expectancy
• Mechanical life expectancy at 20°C 100,000 operations
• Electrical life expectancy at 20°C
50,000 operations min. for a resistive load of 15 A at 250 VAC
50,000 operations min. for an inductive load (cosf = 0.7) of 10 A at 250 VAC
50,000 operations min. for a motor load of 1 HP at 250 VAC
50,000 operations min. for a lamp load of 100 W at 100 VAC
10,000 operations min. for a lamp load of 300 W at 100 VAC
The higher the ambient temperature is, the shorter the Time Switch's
life expectancy will be.
5. Ratings and Performance Characteristics
Supply voltage
24VDC (H5F-B-90)
100 to 240VAC 50/60Hz(other)
Operating voltage range
85 to 110% of rated voltage
Power consumption
Approx.0.5W(H5F-B-90)
Approx.2.4VA(other)
Number of circuits
1(independent)
Separated from power circuit
Circuit
(no-voltage)
Configuration
Contact output(SPST-NO)
Resistive
AC250V 15A
Inductive
AC250V 10A(cosφ=0.7)
–10 to +55°C
Ambient operating
(Avoid freezing or condensation)
temparature
–25 to +65°C
Ambient Storage
(Avoid freezing or condensation)
temparature
Ambient humidity
35 to 85 %
±0.01% ±50ms max.
Total error (Note1)
Cyclic error
Monthly difference 15s (25°C)
5 years min.
10 years min
Memory protection
Note 1: The total error including the repeat accuracy, setting error,variation due to voltage
change, and variation due to temperature change is ±0.01%±0.05s maximum.
Note 2: These figures are accumulated times.
(Power-interruption rate
of 50%) Note2
Minimum setting
interval
Pulse width
Operations
Installation
environment
Altitude
Mechanical
durability
Vibration
Malfunction
durability
Mechanical
durability
Shock
Malfunction
durability
Standards
- 33 -
1min
Can be set to 1to 59s in units of
1 second and to 1 to 60min in
units of 1 minute.
ON/OFF operation:24
(12 sets of ON and OFF
operations)
pulse-output operation:24
Over-voltage category II,
pollution degree 2
(as per IEC61010-1)
MAX. 2,000 m
10 to 55Hz,0. 75mm double
amplitude
10 to 55Hz,0. 5mm double
amplitude
2
300m/s
2
100m/s
UL508(Listing)
CSA C22.2 No.14(cULus)
EN61010-1(IEC61010-1)
EN61326
VDE0106/part100