1. Dimensions and Mounting Dimensions

■ H5F-B (Flush-mounting Model )
● Dimensions
Y92A-48 Dust Cover (sold separately) 
48
■ H5F-FB (Surface-mounting Model)
● Dimensions
Y92A-48E Dust Cover (sold separately)
50

Installation

63.7
6
14
84.8
88.7
Terminal cover
(accesory)
49
42.1
31
Terminal cover
(accesory)
Cutout sections:
(Cut out as required
for wiring.)
● Mounting Dimensions
48
+0.5
45
0
● Mounting Dimensions
(50)
Mounting space
- 29 -
Panel 
Y92F-30 
Flush-mounting  
Adapter(accesory)
R0.5max
Note: 
Pay attention to the  
orientation of the adapter  
when mounting two or more  
time switches in a vertical  
or horizontal.
M4 tapping screws (2; provided) 
<Size of tapping screw hole> 
Thickness of a panel  Size of hole 
0.8 to 1.2mm
1.6 to 4.0mm
[mm]
[mm]
1.5
ø3.6mm
ø3.7mm

Hide quick links: