Power Trim and MerCathode Overload Protection

If an electrical overload on the electrical system occurs, a fuse will burn out (blow). Find and correct the cause before replacing
the fuse.
NOTE: If you must operate the engine in an emergency, turn off and disconnect all accessories from the engine and instrumentation
wiring if you cannot find and correct the cause for the electrical overload or excessive current draw. Replace the fuse. If the fuse
burns out, the electrical overload has not been eliminated. Further checks must be made on the electrical system. Contact your
Cummins MerCruiser Diesel Authorized Repair Facility.
1.
The power trim system is protected from overload by a 110‑amp fuse and a 20‑amp in‑line fuse on the power trim pump.
a
2.
The Quicksilver Three‑Button Power Trim Control Panel, if equipped, is protected from overload by a 20‑amp in‑line fuse.
a -
20‑amp in‑line fuse
3.
The Quicksilver MerCathode System, if equipped, has a 20‑amp in‑line fuse in the wire that connects to the positive (+)
terminal on the controller. If the fuse is burned out (blown), the system will not operate, resulting in a loss of corrosion
protection.
a
Page 22
b
a -
20‑amp in‑line fuse
19834
a -
20‑amp holder
b -
110‑amp fuse
9208
a
90-8M0057081
MARCH 2011
eng