Performance

Model
Fuel Type
Combustion Technology
Recommended heating area ¹
Maximum burn time ¹
Overall heat output rate ²
(min to max)
Average overall efficiency (HHV) ³
(dry cordwood)
Average overall efficiency (LHV) ⁴
(dry cordwood)
Weighted Average overall efficiency ²
(dry cordwood)
Average particulate emission rate ³
Average CO
¹ Recommended heating area and maximum burn time may vary depending on the home's location,
stove location, floor plan, degree of insulation, chimney draft, climate, and wood fuel type, quality,
and moisture level.
² This stove is officially tested and certified by an independent agency for US EPA's cordwood test
method as measured per CSA B415.1-10 stack loss method
³ Higher Heating Value of the fuel
⁴ Lower Heating Value of the fuel
EPA Compliance
This manual describes the installation and operation of the Nectre N65 wood heater. This heater
meets the 2020 U.S. Environmental Protection Agency's cordwood emission limits for wood heaters
sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at
rates ranging from 14,108 to 68,531 BTU/hr.
N65
Dry Cordwood
Non-Catalytic
Up to 200 m² (2,152 sq. ft.)
8-10 hours
14,108 - 68,531 BTU
4.13 kW - 20.08 kW
69.6%
74.5%
67.3%
1.98 g/hr
1.258 g/min
5