Every 2000 Operating Hours; Changing The Hydraulic Oil - Bomag BW 100 AD-5 Operating & Maintenance Instructions

Tandem vibratory roller
Table of Contents

Advertisement

Maintenance – Every 2000 operating hours

8.11 Every 2000 operating hours

8.11.1

Changing the hydraulic oil

170
Perform this maintenance work at
the latest after two years.
The hydraulic oil must also be changed after
major repairs in the hydraulic system.
Always replace the hydraulic oil filter after each
hydraulic oil change. Change the hydraulic oil
filter only after the hydraulic oil change and
after the test run.
Do not start the engine after draining off the
hydraulic oil.
Do not use any detergents to clean the system.
Use only lint-free cleaning cloths for cleaning.
When changing from mineral oil based
hydraulic oil to an ester based biologically
degradable hydraulic oil, you should consult
the lubrication oil service of the oil manufac-
turer, or our customer service for details.
NOTICE!
Risk of damage!
– Perform the oil change when the
hydraulic oil is warm.
– Use only hydraulic oil of the per-
mitted specification
8.3.4 „Hydraulic oil" on page 145.
– Filling quantity:
„List of fuels and lubri-
cants" on page 146.
BW 100 AD-5
Ä Chapter
Ä Chapter 8.4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents