Main Menu No.2: Basic Settings; Sp Table; Sp2-41, 2-42: Thermal Head Energy Control - Ricoh JP3000 Service Manual

Machine code c238
Hide thumbs Also See for JP3000:
Table of Contents

Advertisement

31 October 2001

5.3 MAIN MENU NO.2: BASIC SETTINGS

5.3.1 SP TABLE

No.
Menu Items
2-1 Default print speed
2-2 Default image position
2-10 Ink detection board
2-11 Paper end sensor
2-12 Drum master sensor
2-13 Platen cover sensor
2-14 ADF cover sensor
2-20 Destination setting
2-21 Swap start key for print key
2-22 Double count-up for A3 masters
2-40 T/H energy control by ink temperature
2-41 Thermal head energy control
2-42 Thermal head energy control - economy

5.3.2 SP2-41, 2-42: THERMAL HEAD ENERGY CONTROL

2-41: The default is 7%. This means that during normal printing mode, the thermal
head energy is 93% of the maximum possible (100 – 7).
2-42: The default is 10%. This means that in economy printing mode, the thermal
head energy is reduced by another 10%. With the default settings, this
means that the thermal head energy is 83% of maximum power (100-7-10).
MAIN MENU NO.2: BASIC SETTINGS
Default
3
1 to 5
4
1 to 7
1: -15mm, 2: -10mm, 3: -5mm,
4: 0.0mm, 5: +5mm, 6: +10mm,
7: +15mm
On
Off/On (Off is used for tests, and
for removing ink from the drum –
section 3.8.)
On
Off/On (Off is used for tests.)
On
Off/On (Off is used for tests.)
On
Off/On (Off is used for tests.)
On
Off/On (Off is used for tests.)
-
0: Japan, 1: NA, 2: EU
Off
Off/On
0
0: Not used, 1: Master counter
only, 2: Master counter and print
counter
On
Off/On
7
0 to 50%
10
0 to 43% (☛ 5.3.2)
5-5