31 October 2001
Remarks for Handling the Thermal Head
Pay careful attention to the following remarks when servicing:
•
Do not touch the surface
with bare hands. If this
occurs, clean the
surface with alcohol.
• Do not damage the
heating elements.
Master
• Connect and disconnect the connectors
carefully. Keep them horizontal and
firmly reconnect them.
• Adjust the voltage supplied to match the
specified value for the thermal head.
• Remove any foreign materials
Platen
Roller
• Do not touch the connector
6-17
IMAGE PROCESSING
from the platen roller.
• There are some ICs inside
the metal cover. Do not push
the cover down.
• Do not touch the master film
surface with bare hands.
terminals with bare hands, to
prevent damage from static
electricity.
C238D021.WMF