Section 2: System Installation

Manual Reel
Carefully lower the probe into the well, using the tape guard to prevent damage to the
tape.
Do not use the tape guard in wells larger than 4" (10 cm), as it may fall
down the well.
In wells larger than 4" (10 cm) be careful not to let the tape scrape against the lip of the
well casing.
Electric Reel
1.
Plug power cord into the control box of the reel.
2.
Attach red clip to positive battery terminal, and black clip to the negative battery
terminal.
3.
Turn the speed control dial fully counter-clockwise. Press desired button
(up/down). Slowly rotate the speed control until reel is rotating at the desired
speed.
When winding the tape up on the reel, pay careful attention so
that the tape and/or probe do not get caught or tangled.
Keep hands and loose article of clothing away from chain.
DO NOT operate unit without a guard!
6