Powering On The Device - Huawei AR150 SERIES Quick Start Manual

Enterprise routers
Hide thumbs Also See for AR150 SERIES:
Table of Contents

Advertisement

Huawei AR150&200 Series Enterprise Routers
Quick Start Guide
4: LAN port cable, which is connected to a computer with a network cable (RJ45 connectors).
5: Ground cable. The M4 connector is connected to the AR150/200 and the M6 connector is
connected to ground. The cable is in yellow and green.
l When the AR150/200 is placed on the desktop or installed in a cabinet/rack, the ground
l When the AR150/200 is wall mounted, the ground cable is connected facing left, as shown
6: external power adapter, which is connected to the AC power supply to output DC power to
the device.
Power adapter output power:
l AR150 & AR200 series: 36 W
NOTE
7: A whip antenna, which is installed on a 3G interface to transmit and receive 3G signals.
8: A SIM card, which is installed in the SIM card slot of a device to allow the device to connect
to a 3G network.

2.4 Powering on the Device

This section provides the checklist used to check the AR150/200 before powering on it.
Checklist
No.
1
2
3
4
5
6
7
Issue 03 (2012-06-10)
cable is connected facing downwards, as shown in
interfere with other devices in the cabinet/rack.
in
Figure 2-1
b.
The AC power cable must be secured using a latch.
Item
The power cables and ground cables are copper wires, and
are not spliced or damaged. The cables are safely
connected and in compliance with standards.
The power cables and ground cables are connected safely.
The spring washers of the ground cable terminals are on
the flat washer.
All signal cables to be deployed pass the continuity check. Measure
No signal cables are near the cabinet's heat vents.
The bent part of signal cables cannot be too tight.
The cables in the cabinet are not crossed and the cables
outside the cabinet are bundled.
Both ends of signal cables are clearly labeled and the label
text is in the same direction.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Product Installation
Figure 2-1
a. The ground cable cannot
Method
View
View
View
View
View
View
23

Hide quick links: