E. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Section 12.A (Figure 12.1 for DVP, Figure
12.8 for SLP) for information on effective length of pipe
components.
• Horizontal terminations are measured to the outside
mounting surface (flange of termination cap) (see Figure
4.7).
• Vertical terminations are measured to top of last section
of pipe. See Figure 4.8.
• Horizontal pipe installed level with no rise.
Figure 4.7 Measure to Outside Mounting Surface
Figure 4.8 Measure to Top of Last Section of Pipe
Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20
MEASURE TO SHADED SURFACE
(OUTSIDE MOUNTING SURFACE)
21