Download Print this page

Thermistor Assy / Pcb - Daikin RKM46QVMA Service Manual

Removal procedure 4.6/5.0/6.0/7.1 kw class

Advertisement

Si001654EA

4. Thermistor ASSY / PCB

Warning
Step
1. Remove the thermistor
ASSY.
1
Pull out the 2 clamps
and push the 2
projections of the
clamps from the back of
the electrical box and
pull them out.
2
Remove the earth/
ground screw.
3
Disconnect the 3
terminals for power
supply.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Earth/ground screw
Top view
[S]
[HL1]
[HN1]
Projection of
clamp
Clamp
(R23204)
(R24116)
(R23206)
Thermistor ASSY / PCB
Points
[HL1], [HN1], [S]: terminal board
11

Hide quick links: