Download Print this page

Electrical Box - Daikin RKM46QVMA Service Manual

Removal procedure 4.6/5.0/6.0/7.1 kw class

Advertisement

Electrical Box

3. Electrical Box
Warning
Step
1
Remove the 3 screws,
and then the wire
fixture.
2
Remove the 7 screws
on the terminal board
and disconnect the
connecting wire and
power supply wire.
3
Disconnect the
connector [S20] and
pull out the clamp.
8
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Connecting wire
[S20]
Wire fixture
(R23194)
Terminal board
Power supply wire
(R23195)
[S20]: electronic expansion
Clamp
(R23196)
Si001654EA
Points
valve coil
When reassembling,
connect the connectors in
the following order.
(1) [S40]
(2) [S80] (Heat Pump only)
(3) [S20]
(4) [S70]
Removal Procedure

Hide quick links:

Advertisement

loading