Right Side Panel / Electrical Box - Daikin 2MXS18NMVJU Service Manual

Outdoor unit removal procedure 18000/24000/28000/34000/36000 btu/h class
Hide thumbs Also See for 2MXS18NMVJU:
Table of Contents

Advertisement

Right Side Panel / Electrical Box

3. Right Side Panel / Electrical Box
Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1. Remove the terminal
cover.
1
Remove the 2 screws
of the terminal cover.
2
Open the terminal cover
and pull down to
unfasten the 2 hooks.
3
Remove the terminal
cover.
2. Remove the connecting
wires and the power
supply wire. (for U.S.
models)
1
Slide the drip proof
plate up to unfasten the
2 hooks and remove it.
6
disassembling work.
Procedure
Drip proof plate
Terminal cover
(R22290)
Hook
(R22291)
Hook
(R22292)
Si121558EC
Points
 The shape of the terminal
cover varies depending on
the model.
 When reassembling, make
sure that the 2 hooks are
securely fastened.
 When reassembling, make
sure that the 2 hooks are
securely fastened.
Removal Procedure
(R25931)

Advertisement

Table of Contents
loading