Pcbs - Daikin 2MXS18NMVJU Service Manual

Outdoor unit removal procedure 18000/24000/28000/34000/36000 btu/h class
Hide thumbs Also See for 2MXS18NMVJU:
Table of Contents

Advertisement

PCBs

4. PCBs
Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1. Remove the service
monitor PCB.
1
Remove the screw and
remove the switch
cover.
2
Unfasten the 4 hooks
and remove the service
monitor PCB cover.
3
Disconnect the 2
connectors [S501] and
[S502] from the service
monitor PCB.
12
disassembling work.
Procedure
Service monitor
PCB cover
Hook
[S502]
[S501]
Service monitor PCB
Switch cover
(R22309)
Hook
(R22311)
(R22313)
Si121558EC
Points
 When reassembling, make
sure that the 2 hooks are
securely fastened.
 When reassembling, make
sure that the 4 hooks are
securely fastened.
[S501], [S502]: to main PCB
Removal Procedure
Hook
(R22310)
(R22312)

Advertisement

Table of Contents
loading

Table of Contents