Display; Overall View - Ariston ALTEAS ONE Net Series Installation And Servicing Instructions

Condensing wall-hung gas boiler, including cube room sensor wireless
Table of Contents

Advertisement

PRODUCT DESCRIPTION

DISPLAY

3
20,5°
00 02 04 06 08 10 12 14 16 18 20 22 24
60°
COMFORT
Date and time
Keylock active
D.H.W. set temperature and indication of
the set temperature level
C.H. set temperature and indication of the
set temperature level
Warning scheduled maintenance
Heating operation set
Heating operation active
D.H.W. operation set
D.H.W. operation active
Flame detected with indication of power
used
Digital pressure gauge (bar)
Scrolling text displaying operation as
information
Error wsignals
The display show the code and
description
AUTO function activated
Hot Water Comfort activated
CH Schedule programming
(set display: boiler base - see user's menù)
CH Schedule programming
(set display: boiler complete - see user's menù)
Internal temperature displayed for
set zone. (with bus device connected
- optional)
External temperature displayed
ECO mode
WIFI active
WIFI connected to the local network,
but without access to the server
WIFI not confi gured
Solar temperature probe connected -
option
8
/
26/10/15
12:30
10°
82°
1,5 bar
AUTO
Riscaldamento attivo
26/10/15 12:30
42°
Central heating
ALERT
AUTO
COMFORT

Overall view

1
2
3
4
5
6
7
8
9
10
1.
Flue connector
2.
Air relief valve
3.
C.H. Flow temperature probe
4.
Main heat exchanger
5.
Detection Electrode
6.
Silencer
7.
Secondary heat exchanger
8
Condensate trap
9.
C.H. pressure relief valve
10. Gas valve
12. C.H. circuit fi lter
13. Modulating circulation Pump with air release
valve
14. D.H.W. Flow switch
15. Diverter valve
16. Water pressure sensor
17. C.H. Return temperature probe
18. Modulating Fan
20. Combustion Analysis Test Point
20
18
17
16
15
14
13
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alteas one net 30Alteas one net 35

Table of Contents