Technical Area; Accessing The Menus - Ariston ALTEAS ONE Net Series Installation And Servicing Instructions

Condensing wall-hung gas boiler, including cube room sensor wireless
Table of Contents

Advertisement

TECHNICAL AREA

TECHNICAL AREA - reserved for qualifi ed technician
Accessing the Technical Area allows for setting/confi guring the
device according to the specifi c requirements of every installation
procedure.
It also provides important information relating to the effi cient
operation of the boiler.
The Technical Area comprises various display windows that allow
for directly accessing the parameters Intervening in each single
product installation/confi guration phase.
The parameters relating to each single menu are listed in the
following pages.
The various parameters can be accessed and modifi ed using the
button , the programming Keys
(see picture
below).
40
COMFORT
CASCADE
Central Heating
a
b
a.
ESC button (Back)
b.
Programming keys
c.
OK button
For accessing the Technical Area
simultaneously press the ESC
and
buttons for 5 seconds; the
display will visualise the request
for entering the technical code.
Press the programming key b
button .
To move within the Technical Area,
b
and press
button to access the selected window.
Press the programming key b
press
button to access it.
To modify the value of a parameter,
and press
button to store the value.
Use the ESC
button to exit a parameter without storing the
modifi cation and for returning to the normal viewing mode.
Technical area
Language, date and time
Complete Menu
Configuration Wizard
Service
Faults
38
/
b
ESC button
and the
70
1,5 bar
AUTO
b
c
Insert code
Insert technical code
222
Save
to select 234 and press the
press the programming key
to select a parameter and
press the programming key b
Example:
Modifi cation of parameter
2.3.1 Max. Adjustable Central Heating Power
Proceed as follows:
1. Simultaneously press the ESC
seconds; the display will visualise the request for entering the
technical code.
Press the programming key b
2.
and select code 234.
3. Press the
button; the
display
will
visualise
available windows.
Press the programming key b
4.
to select the Complete Menu.
5. Press the
button to access;
the display will visualise the
available menus.
Press the programming key b
6.
to select Menu 2 - Boiler
parameters.
7. Press the
button. The
display
will
visualise
available sub-menus.
Press the programming key b
8.
to select 2.3 - Central
heating 1.
9. Press the
button to
access.
The display will visualise the
parameters relative to sub-
menu 2.3.
Press the programming key
10.
b
to select parameter
2.3.1 - Max. C.H. Adjustable.
11. Press the
button to access
the parameter.
The display will visualise the
value of the parameter (50%)
in addition to the minimum
and maximum values allowed.
Press the programming key b
12.
to select the new value,
e.g. 46%.
13. Press the
button to store
the modifi cation.
(To exit the parameter without storing the modifi cation, press
the ESC
button).
14. Press the ESC
button to return to the normal viewing
mode.
and
buttons for 5
Technical area
Language, date and time
Complete Menu
Configuration Wizard
the
Service
Faults
Menu
0
Network
1
<Not Available>
2
Boiler Parameters
3
<Not Available>
4
Zone1 Parameters
2 Boiler Parameters
the
2.0
General
2.1
Free parameters
2.2
Settings
2.3
Central Heating-1
2.4
Central Heating-2
2.3 Central Heating-1
2.3.0
Max CH Absolute
2.3.1
Max CH Adjustable
2.3.2
<Not Available>
2.3.3
<Not Available>
2.3.4
<Not Available>
2.3.1 Max CH Adjustable
50 %
Maximum value
Minimum value
2.3.1 Max CH Adjustable
46 %
Maximum value
Minimum value
62
50
100%
0%
100%
0%