Ariston ALTEAS ONE Net Series Installation And Servicing Instructions page 43

Condensing wall-hung gas boiler, including cube room sensor wireless
Table of Contents

Advertisement

description
5.
2. 5 Maximum CH
Temperature Zone 2
5.
2. 6 Minimum CH
Temperature Zone 2
5.
3 Z2 DIAGNOSTICS
5.
3. 4 Heat request Zone 2
6
ZONE 3 PARAMETER
6.
0 SETPOINT
6.
0. 2 T set Zone 3
To set only with Fixed Flow Temperaure of
Thermoregulation (see 521)
6.
2 ZONE 3 SETTING
6.
2. 0 Zone 3 Temperature
range
6.
2. 1 Thermoregulation
To enabled
thermoregulation press
Auto button.
On the dispaly will
appear the symbol
AUTO
6.
2. 2 Slope
See parameter 422
Only enabled when an outdoor sensor is installed
When an outdoor sensor is used, the boiler
calculates the most suitable delivery temperature,
taking into account the outside temperature and
type of system. The type of curve should be
selected in correspondence with the projected
temperature of the system and the nature of the
dispersions present in the structure. For high-
temperature systems, one of the curves depicted
below may be chosen.
value
from 35 to 82 °C
82
(Param. 520 = 1)
from 20 to 45 °C
45
(Param. 520 = 0)
from 35 to 82 °C
35
(Param. 520 = 1)
from 20 to 45 °C
20
(Param. 520 = 0)
0 = OFF
1 = ON
from 35 to 82 (°C)
70
0 = from 20 to
1
45°C
(low temperature)
1 = from 35 to 82°C
(high temperature)
0 = Fixed Flow
1
Temperature
1 = Basic
Thermoregulation
2 = Room Temp
only
3 = Outdoor Temp.
only
4 = Room +
outdoor
Temp.
from 1.0 to 3.5
1.5
(high temperature)
from 0.2 to 0.8
0.6
(low temperature)
description
6.
2. 3 Off set
Auto Function active
To adapt the heating curve to the system require-
ments, shift the curve in parallel so that the calcula-
ted fl ow temperature is modifi ed, in addition to the
room temperature.
By accessing the parameter and pressing the
button b, it is possible to shift the curve in a
parallel direction. The shifting value can be read
on the display: from -14 to +14 for high-temperature
devices, or from -7 to 7 for low-temperature devices.
Each step corresponds to a 1°C increase/decrease
In the fl ow temperature with respect to the set-point
value.
6.
2. 4 Room Infl uence
Proportional
Auto Function active
If setted = 0 the room temperature doesn't
infl uence the calculation of the set-point.
If setted = 20, the room temperature has the
maximun infl uence to calculate the set-point
- only active when the BUS device is connected
6.
2. 5 Maximum CH
Temperature Zone 3
6.
2. 6 Minimum CH
Temperature Zone 3
6.
3 Z3 DIAGNOSTICS
6.
3. 0 < Not Available>
6.
3. 4 Heat request Zone 2
8
SERVICE PARAMETERS
8.
0 BOILER STATISTICS - 1
8.
0. 0 Diverter valve cycles No. (nx10)
8.
0. 1 Time of circulator on (nx10)
8.
0. 2 Boiler circulator cycles No. (nx10)
8.
0. 3 Boiler Life Time (hx10)
8.
0. 4 Time of fan ON (hx10)
8.
0. 5 Fan cycles No. (nx10)
8.
0. 6 CH fl ame detection (nx10)
8.
0. 7 DHW fl ame detection (nx10)
8.
1
BOILER STATISTICS - 2
8.
1. 0 Hours Burner On CH (hx10))
8.
1. 1 Hours Burner On DHW (hx10)
8.
1. 2 Number of Flame Faults (nx10)
8.
1. 3 Numbeer of ignition Cycles (nx10)
8.
1. 4 Heat request Duration
8.
2 BOILER
8.
2. 1 Fan Status
8.
2. 2 Fan Speed - x100 RPM
8.
2. 3 Pump speed - NOT ACTIVE
TECHNICAL AREA
value
from - 14 to + 14 (°C)
0
(high temperature)
from - 7 to + 7 (°C)
0
(low temperature)
from 0 to 20
20
from 35 to 82 °C
82
(Param. 620 = 1)
from 20 to 45 °C
45
(Param. 620 = 0)
from 35 to 82 °C
35
(Param. 620 = 1)
from 20 to 45 °C
20
(Param. 620 = 0)
0 = OFF
1 = ON
0 = OFF
1 = ON
/