Ariston ALTEAS ONE Net Series Installation And Servicing Instructions page 62

Condensing wall-hung gas boiler, including cube room sensor wireless
Table of Contents

Advertisement

MAINTENANCE GUIDE
Pull the assembly towards you
4
Remove the two screws and remove the electrode
4
5
62
/
Remove the ceramic fi bre.
Remove the four screws and pull the burner toward you.
Always replace the burner gasket (*).
6
Verify and replace the other gaskets if they are damaged
or showing signs of deterioration
4.3 Fan
Tools
Remove the silencer (see 4.3 - 1)
Isolate the gas supply.
Disconnect the gas pipe (see 4.3 - 2)
1
(*)
TIME
15 min

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alteas one net 30Alteas one net 35

Table of Contents