Hydraulic Unit - Ariston ALTEAS ONE Net Series Installation And Servicing Instructions

Condensing wall-hung gas boiler, including cube room sensor wireless
Table of Contents

Advertisement

MAINTENANCE GUIDE

3. HYDRAULIC UNIT

3.1 RIGHT HAND HYDRAULIC BLOCK ASSEMBLY
1
1
2
2
3
3
Legend:
1 - Diverter valve motor
2 - Diverter valve
3 - By-pass
4 - D.H.W. fl ow switch assembly
5 - C.H. drain valve
6 - Central heating fi lter
7 - Pump
8 - Water pressure sensor
9 - Auto air vent
10 - Central Heating return
11 - Cold water inlet (D.H.W.)
3.2. 3 Way valve unit
Tools
Drain the boiler (see 3.3).
Unplug the diverter valve cable
1
50
/
9
9
8
8
4
4
7
7
6
6
1 0
1 0
5
5
TIME
5 min
Rotate clockvise to unhook the locking ring.
2
Remove the 3 way valve motor.
3
Remove the clip and lift the diverter valve from the assem-
bly.
4
WHEN REASSEMBLING, ENSURE THE DIVERTER VALVE IS
ALIGNED CORRECTLY.