Contact specialized personnel for error codes
Code
Description
Software error-error on start up or
001
corrupted software
050
Short-circuit in temperature probe
051
Open temperature probe.
Initial Fill Error. Initial fill time was
100
more than 11 minutes after power
up.
Error on refill
101
Tank did not refill within 3 minutes.
102
Unwanted fill;
Heater open, high limit thermostat,
201
or Solid State Relay (SSR) fault
255
Touch pad error
INSERT
BREW
BASKET
!  Never attempt to remove a brew basket-during brew-this is a safety feature
Go to fetco.com for the latest versions of all information

Error Codes

Possible Cause
Improper start-up or
shutdown
Probe failure.
Bad probe connection, or
probe failure.
Water supply flow rate is
too low.
Water supply flow rate is
too low.
Possible leak in tank,
fitting, or valve.
Failure of: heating
element, SSR, high Limit
or low voltage
Usually from longer than 2
min contact. Or faulty
reassembly after service
Brew basket must be in
place
This is a
SAFETY FEATURE
User Guide & Operator instructions
Page 14
Corrective Action
Restart , if still fault: reload software
Replace probe.
Check all connections. Replace probe
if necessary.
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter...)
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter...)
Occurs during pre-fill, low probe is
uncovered
Check and replace heating elements if
necessary.
Restart , if still fault: reload software.
If mechanical: reassemble correctly
Insert brew basket into brewer rails to
enable brewer
P171 NEW MARCH 2018