Error Codes - Fetco CBS-2131XTS User Manual

Hide thumbs Also See for CBS-2131XTS:
Table of Contents

Advertisement

Contact specialized personnel for error codes
Code
Description
Software error-error on start
001
up or corrupted software
050
Shorted temperature probe
051
Open temperature probe.
Initial Fill Error. Initial fill
100
time was more than 11
minutes after power up.
Error on refill
101
Tank did not refill within 3
minutes.
Unwanted fill;
Occurs between brews
102
when the fill valve
operates.
Lower liquid level probe
107
Fault
Heater open, high limit
201
thermostat, or Solid State
Relay (SSR) fault
255
Touch pad error
Regular 1
Regular 2
INSERT
BREW
BASKET
!
Never attempt to defeat or override a brew basket-locking feature
Possible Cause
Improper start-up
or shutdown
Probe failure.
Bad probe
connection, or
probe failure.
Water supply flow
rate is too low.
Water supply flow
rate is too low.
Possible leak in
tank, fitting, or
valve
-Tank not filling
-Orange wire to
temperature probe
disconnected
-Very pure water
Failure of: heating
element,SSR,high
Limit or low voltage
Usually from longer
than 2 min contact.
Or faulty reassembly
after service
3.00
06:00
3.00
06:00
Brewbasket must
Decaf 1
be in place
3.00
06:00
Decaf 2
3.00
06:00

Error Codes

Corrective Action
Restart , if still fault: reload
software
Replace probe.
Check all connections.
Replace probe if necessary.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter...)
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter...)
Check for internal leaks
Occurs after prefill
-Low probe is uncovered
-Wires are reversed
-Set LLC sensitivity to HIGH
see MENU—GENERAL-LLC
Check and replace heating
elements if necessary.
Restart, if still fault: reload
software. If mechanical:
reassemble correctly
Insert brewbasket
14
How to Clear
Error Codes
TO CLEAR FAULT,
Make repairs as required
Below is the only way to
clear error codes
1) Enter
"PROGRAMMING"
2)Scroll left to "OTHER"
3)Scroll down to
"ERROR CODES"
4)Scroll down to "Display
Errors"
5)Scroll left to "Reset
Errors"
6)Scroll down to "Reset"
7)Follow directions
shown on screen.
Merely toggling ON/OFF
switch will not clear error
codes.
Error codes must be
cleared by entering
PROGRAMMING and
using the menus!

Advertisement