Error Codes - Fetco CBS-2100XTS Users Manual And Operator Instructions

Extractor touch screen
Table of Contents

Advertisement

COUNTER Screen, Definition
Total brews on left side
Actual brews on left side
Total volume produced by left side brewer
Actual Bypass used on left side
Total volume of left bypass
Total brews on right side
Actual brews on right side
Total volume produced by right side brewer
Actual Bypass used on right side
Total volume of right bypass
Total cycles activated by fill valve
Total cycles activated by fill valve
Total heater cycles activated
Total time heater has been energized
Contact specialized personnel for error codes
Code
Description
Software error-error on start
001
up or corrupted software
Short-circuit in
050
temperature probe
051
Open temperature probe.
Initial Fill Error. Initial fill
100
time was more than 11
minutes after power up.
Error on refill
101
Tank did not refill within 3
minutes.
102
Unwanted fill;
Fault
107
Lower liquid level probe
Heater open, high limit
201
thermostat, or Solid State
Relay (SSR) fault
255
Touch pad error
INSERT
BREW
BASKET
!  Never attempt to defeat or override a brew basket-locking feature-this is a safety feature
Go to fetco.com for the latest versions of all information

Error Codes

Possible Cause
Corrective Action
Improper start-up
Restart , if still fault: reload
or shutdown
software
Probe failure.
Replace probe.
Bad probe
Check all connections.
connection, or
Replace probe if necessary.
probe failure.
Watch for short potting
Water supply flow
during brew cycle.
rate is too low.
Investigate cause of low flow
rate. (Clogged water filter...)
Watch for short potting
Water supply flow
during brew cycle.
rate is too low.
Investigate cause of low flow
rate. (Clogged water filter...)
Possible leak in
Occurs during pre-fill, low
tank, fitting, or
probe is uncovered
valve.
Occurs during pre-fill, low
probe is uncovered , or
Tank not filling
wires are reversed low / high
probe
Failure of: heating
Check and replace heating
element, SSR, high
elements if necessary.
Limit or low voltage
Usually from longer
Restart , if still fault: reload
than 2 min contact.
software. If mechanical:
Or faulty reassembly
reassemble correctly
after service
Brew basket
must be in place
Insert brew basket into
brewer rails to enable
This is a
brewer
SAFETY
FEATURE
Page 12
Left Brews
Left Brew activated
Left Brew [litr]
Left Bypass activated
Left Bypass [litr]
Right Brews
Right Brew activated
Right Brew [litr]
Right Bypass activated
Right Bypass [litr]
Fill valve Activated
Fill Valve [litr]
Heater Activated
Heater "ON" time
Touch To Return
TO CLEAR FAULT,
Make repairs as required
Below is the only way
1) Enter
"PROGRAMMING"
2)Scroll left to "OTHER"
3)Scroll down to
"ERROR CODES"
4)Scroll down to "Display
Errors"
5)Scroll left to "Reset
Errors"
6)Scroll down to "Reset"
7)Follow directions
shown on screen.
Merely toggling ON/OFF
switch will not clear error
codes.
Error codes must be
cleared by correcting the
fault and entering
PROGRAMMING and
using the menus!
Part A-User Guide & Operator instructions
13
13
39
0
0
41
41
0
0
0
0
0
0
0:00
How to Clear
Error Codes
to clear error codes:
P130 Part A Rev. 003 July 2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-2141xtsCbs-2142xtsL4s-10

Table of Contents