Error Codes - Fetco C212113 ZURICH TS Users Manual And Operator Instructions

Cbs-2121 zurich ts series. automatic touchscreen coffee brewer with pourover feature
Table of Contents

Advertisement

ERROR CODES

#
Error
2
Internal Error (software)
3
CRC Error
50
Shorted temperature probe
51
Open temperature probe or circuit
100
Initial fill error when >10 minutes fill time
101
Refill error-if not filled in>5 minutes time
102
Unwanted fill error
201
Heater open (temp.rise<2° in 10 minutes) Bad heater, open one-shot fuse
201
Heater short (temp.rise>5° with heat "off") Bad Thermostat or heating element
255
Keyboard Error-pressed>2 minitues
Go to fetco.com for the latest versions of all information
Description
Improper startup or shutdown
Internal data memory malfunction
Probe failure
Probe failure, bad connection
Water supply rate too low-(Toggle Off/On)
Water supply rate too low or is off
Possible leak in tank or water connection
Touch pad or connection bad
Page 10
Error codes must be corrected!
Diagnose the cause and repair.
To clear: reboot the brewer by
toggling power switch:"OFF/ON"
P169 MARCH 2018

Advertisement

Table of Contents
loading

Table of Contents