Start Up The Idpa; Start Up The Idpa From Dell Server; Start Up The Idpa From Idrac - Dell EMC IDPA DP4400 Service Procedures

Hide thumbs Also See for IDPA DP4400:
Table of Contents

Advertisement

| NIC Slot 2
| NIC Slot 2

Start up the IDPA

Start up the IDPA from Dell server

Start up the IDPA from iDRAC

| 1
| Up
| Gigabit 2P I350-t Adapter
| 2
| Down
| Gigabit 2P I350-t Adapter
2. Verify that the status information for the NIC matches the information shown in
the example output.
You can start the IDPA from Dell server or through iDRAC.
Switch on the power button present on the Dell server.
Note
No other action is required to start the IDPA model DP4400.
Procedure
1. Turn on the iDRAC and log in to iDRAC from its UI using
password.
2. Click the Power On System button.
Note
The ESX UI will be accessible within a maximum time of 15 minutes.
3. Login to ESXi UI.
The ESX exits from maintenance mode and the DataProtection-ACM VM starts
all the VMs present in IDPA in the following order, by default:
a. DataProtection-VSCA
b. DataProtection-ACM
c. DDVE
d. AVE
e. DPC
f. DPADatastoreServer
g. DPAApplicationServer
h. DPSIndexMaster
i. CDRA
j. AVProxy
Note
You can also observe the activity from the Recent tasks section at the bottom
of ESX UI page.
4. Connect to the ACM by accessing the https://<ACM_IP>:8543 URL from the
browser.
Remove and replace assemblies
|
|
user and iDRAC
root

Start up the IDPA

67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents