Remove And Replace Nic Cards; Network Daughter Card; Network Interface Controller (Nic) Ports; Identifying A Failed Nic From The Acm - Dell EMC IDPA DP4400 Service Procedures

Hide thumbs Also See for IDPA DP4400:
Table of Contents

Advertisement

=========|
| 0-0| Online| OK
| 0%
|
| 1-1| Online| OK
| 0%
| *

Remove and replace NIC cards

Network daughter card

Network Interface Controller (NIC) ports

Identifying a failed NIC from the ACM

acme-dp4400-ACM:~ # showfru network
Collecting Data............
______________________________________________________________________________
| Name
|=============================================================================|
| NIC Integrated 1| 1
| NIC Integrated 1| 2
| NIC Integrated 1| 3
| NIC Integrated 1| 4
| NIC Slot 1
| NIC Slot 1
| NIC Slot 1
| NIC Slot 1
| NIC Slot 2
| SSDSCKJB120G7R| PHDW739100YV150A| N201DL43
| SSDSCKJB120G7R| PHDW739101RK150A| N201DL43
2. Verify that the status for the BOSS card is "OK". Verify that the state for both
M.2 cards is "Online" and the statuses are "OK".
The network daughter card (NDC) is a small, removable mezzanine card, which
provides the flexibility of selecting different network connectivity options. The
network interface controller (NIC) ports that are integrated on the NDC provide
network connectivity.
The DP4400 supports up to four SFP+ ports that support up to 10 Gbps that are
integrated on the network daughter card (NDC) .
If the NIC is suspected of failing, you can check the web UI or use the FRU command
line verification from the ACM.
Procedure
1. Access the web UI and check for alerts in the Health screen. Click an alert for
more details.
2. From the ACM, use SSH to connect to the ACM command line by typing: ssh
[administrator name]-dp4400-[ACM url]
For example: ssh admin@acme-dp4400-ACM.lab.acme.com
Once connected, the screen displays a command line corresponding to the
ACM.
3. At the command line, type the following command: # showfru network
The screen displays that the system is collecting data. When the data collection
is completed, the screen displays status information for the ports on the NIC.
| Port| Link Status| Model Name
| Up
| Ethernet 10G 4P X710 SFP+ rNDC
| Error
| Ethernet 10G X710 rNDC
| Down
| Ethernet 10G X710 rNDC
| Down
| Ethernet 10G X710 rNDC
| 1
| Down
| Ethernet Converged Network Adapter X710|
| 2
| Down
| Ethernet Converged Network Adapter X710|
| 3
| Down
| Ethernet Converged Network Adapter X710|
| 4
| Down
| Ethernet Converged Network Adapter X710|
| 1
| Up
| Gigabit 2P I350-t Adapter
In this example, port 2 of Integrated NIC 1 is faulted, indicating it needs to be