Wiring plan, connecting
the transmitter
(see also "Application
example")
Be careful the polarity of
the cables
14

5.2. Connection procedure

The following figure shows the wiring plan connecting the
transmitter:
1. Prepare the cable for connecting (see Figure 2.).
2. Loosen the screw in the cover of the cable socket
connector and remove it. (see Figure 1., 4.)
3.
Put the screwdriver end into the hole and lift out the
socket from the housing slightly (see Figure 1., 5.).
4. Put through the prepared cable the cable gland
components and the housing (see Figure 1.,3.).
5. Connect the wire ends to the screw terminals according
to the wiring plan.
6. Insert the socket into the socket housing
(see Figure 1.,1.).
7. Tighten the compression nut of the cable entry
(see Figure 1., 3.).
8. Turn the screw in the socket connector
(see Figure 1., 4.).
9. Push the socket connector onto plug connector on the
instrument (see Figure, Chapter 5.3.).
Do not forget the sealing between the plug and the socket!
10. Turn the screw in the cover of the cable socket
connector and tighten it (see Figure, Chapter 5.3.).