Autodiagnostics; General Safety; General Outline; Technical Specifications - BFT SUPER MA Instruction Manual

Table of Contents

Advertisement

Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an "Instruction Manual" which should be read
carefully as it provides important information about safety, installation,
operation and maintenance.
This product complies with the applicable technical standards and regula-
tions regarding safety. We confirm that it complies with the following
European directives: 73/23/CEE - 93/68/CEE, 89/336/CEE - 91/236/CEE
- 92/31/CEE - 93/68/CEE, 98/37/CEE. Where applicable, it also complies
with technical standards EN60335-1, PrEN12453, PrEN12445.
IMPORTANT
For the operations of wiring and installation, refer to the regulations in effect
and, in any case, to the principles of proper workmanship.
IMPORTANT
Any operation on the parts relative to automation must be carried out by
qualified personnel (the installer).

1) AUTODIAGNOSTICS

The control unit runs a check on the operating relays and safety mecha-
nisms (photocells, sensor ridge, etc.) before performing opening and
closing cycles. If the check fails the green led DL2 (control unit ON) goes
out and the control unit remains in the alarm condition. Disconnect from the
power mains and check the wiring. Power it again and run the autodiagnostic
program with Unipro. If this check give the OK! press the start command.
If the led DL2 goes off again, a relay has failed. Repair or replace the circuit.
2) CONNECTION OF PHOTOCELLS AND SENSOR RIDGE:
By convention, refer to a receiver (Rx- fig.6) with 5 terminals of which
terminals 1 and 2 are for the 24V AC power supply, terminal 3 is shared,
terminal 4 is the normally closed contact when at rest, terminal 5 is the
normally open contact when at rest. The contact is not powered.
3) LEGEND
RX: receiver photocells or infrared ridges.
TX: transmitter photocells or infrared ridges.
The transmitters should be connected to terminals 20-21 of SUPER MA.
The receivers should be connected to terminals 19-20 of SUPER MA.
- Fig.7 shows connection of SUPER MA with no safety device.
- Fig.8 shows connection of SUPER MA with 1 safety device with verified
ADMAP.
- Fig. 9 shows connection of SUPER MA with 1 safety device with verified
opening.
- Fig.10 shows connection of SUPER MA with 1 safety device with verified
closing.
- Fig.11 shows connection of SUPER MA with 2 safety devices with
verified ADMAP.
- Fig.12 shows connection of SUPER MA with 2 safety devices with
verified opening.
- Fig.13 shows connection of SUPER MA with 2 safety devices with
verified closure.
- Fig.14 shows connection of SUPER MA with 3 safety devices with
verified ADMAP.
- Fig.15 shows connection of SUPER MA with 3 safety devices with
verified safety opening.
- Fig.16 shows connection of SUPER MA with 3 safety devices with
verified safety closing.
- Fig.17 shows connection of SUPER MA with 2 devices: 1 safety device
with verified opening and the other with verified ADMAP.
- Fig.18 shows connection of SUPER MA with 3 safety devices: 1 with
verified opening, 1 with verified closing and the other with verified
ADMAP.
- Fig.19 shows connection of SUPER MA with 4 devices: 1 safety device
with verified opening and the other with verified ADMAP.
- Fig.20 shows connection of SUPER MA with 5 safety devices: 1 with
verified opening, 1 with verified closing and the other with verified
ADMAP.

4) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
• Keep the instructions together with the technical brochure for future
reference.
• This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting
SUPER MA
SUPER MA
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
• The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
• The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and
subsequent amendments.
• Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
• Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing.
• Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised
by the company.
• Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation
operation area.
• Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
• Anything which is not expressly provided for in the present instructions,
is not allowed.

5) GENERAL OUTLINE

The SUPER MA control unit is supplied by the manufacturer with standard
setting. Any changes must be set by means of the UNIPRO programmer.
This Control unit supports the entire EELINK protocol, including the
programmer self-supply from the control unit. These are its main features:
- Control of one or two motors up to 600W power.
- Electronic torque setting.
- Adjustable electrodynamic braking.
- End-of-run speed slow-down.
- Separate opening / closing limit-switch inputs for each motor.
- Output for zone light.
- Separate inputs for safety devices.
- 12V output for click or suction-type electric lock.
- Output for timer piloting.
- Clock input.
- Connector for traffic-light board / motor preheating.
The board is provided with a removable terminal board for easier
maintenance and replacement. This is supplied with a series of prewired
jumpers to make work easy for the installer.
The jumpers relate to the following terminals:22-34, 22-35, 22-36, 23-29,
23-30, 23-31, 24-32, 32-33, 37-38, 37-39, 37-40, 37-41. If the above
terminals are used, remove the respective jumpers.

6) TECHNICAL SPECIFICATIONS

Power supply: ................................................................ 230V±10% 50Hz*
Mains/low voltage insulation: ....................................... > 2MOhm 500Vdc
Dielectric strength: .................................. mains/bty 3750Vac for 1 minute
Motor output current: ........................................................ 3.5A+3.5A max
Motor relay commutation current: ....................................................... 10A
Maximum motor power: ....................................................... 600W + 600W
Zone/courtesy light: .................................................................. max 300W
Supply to accessories: .................................. 24Vac (1A max absorption)
Electric lock: ................................................ 12Vdc (0.5A max, 2A for 3 s)
Light/alarm output with free n.o. contact: ........................... max 1A 24Vdc