OIT500-F113-B12-CB3
Mounting and Installation
3.2.3

Mounting the Device

The device has a preassembled mounting base with four symmetrically positioned M6 threads
on the base of the housing for easier installation.
The illustration below shows all the relevant housing dimensions in mm:
10
Figure 3.13
Mounting and Aligning the Device
1. Mount the device to enable easy access to the sensor connections for configuration with the
associated operating software.
2. Roughly position the device to face the code sheet.
3.2.4

Mounting the Code Sheet

Aligning/Adjusting Code Sheets
The OIT system is set to a reading distance of 380 mm by default.
Mount the code sheets parallel with the front panel, so that the lens faces the code sheet. The
tilt angle must not exceed 10°.
68
20
Dimensions of the OIT500 system
256
57
4xM6
OIT500
23