Connection Examples - UR FOG FAST 02 Installation And Use Manual

Table of Contents

Advertisement

SHOOTS
4
shooting input.
Putting this input to positive, if Fast 02 or 03 is hot and armed, starts fog emission for the set time (see programming
section shooting time)
GND
5
Negative reference connected to terminal 1
OUTPUTS
EMPTY
6
Output empty cylinder
This output (NPN Open Collector) closes towards negative direction when at least one of the two
cylinders is empty.
Fault
7
Fault output
This output (NPN Open Collector) closes towards negative when there is a serious malfunction ( such
as batteries expired, fault of power supply or temperature control fault), which compromises the
functioning of the device and which requires a technical action
Tamper
8
Tamper output
This output (NPN Open Collector) closes towards negative direction when you open the door cylinders
or when the accelerometer detects a sudden movement (such as the detachment from the wall)
9
GND
Negative reference connected to terminal 1
To comply with the requirements of the reference standard EN50131-8
Remember, it is necessary to connect all three outputs to an alarm central or an
electronic panel that can see all those information in real time and take proper action.
In order to avoid accidental activation with subsequent fog emission, the inputs are in
"negative security", for this reason the disconnection of a wire does not cause
activation.
So it is necessary to check carefully the reliability of connections and protect the cables
to the control panel to avoid the risk of accidental damages.
10
CONNECTION EXAMPLE
The diagrams and examples below are intended only to a "better understanding" the operation of
the inputs / outputs. None of the diagrams below represents the "single scheme to perform" as, in
respect of the reference standard EN50131-8, there are precise indications and only using all inputs
and outputs on the PCB it is possible to respect the standard.
If UR Fog is used as "ANTI-ROBBERY" device, it is necessary a careful assessment of the risks by a
security consultant.
A
Example of connection UR Fog inputs with outputs of a central anti-theft standard
B
Example of connection for anti-robbery use with external power supply
C
Example of connection of the UR Fog outputs to drive LEDs and / or relays
D
Example of connection of the UR Fog outputs with inputs of an antitheft normally opened
E
Example of connection of the UR Fog outputs with balanced inputs of an antitheft
Installation and use manual models FAST 02 e FAST 03
rev 1.0.0 October 2013
Page 8 di 19