FBD 77 Series Installation & Operation Manual page 44

Hide thumbs Also See for 77 Series:
Table of Contents

Advertisement

Error #051, 052, 053, 054: Safety Fill Error
A barrel filled continuously for more than two minutes.
1
Run the fill diagnostic sequence to determine the reason for the failure.
Error #061, 062, 063, 064: Beater Low Error
A beater motor stalled during operation.
Check the brix in the barrel. If low, check the brix at the sample valve and adjust if needed. Drain
1
and refill the barrel.
Check the fault code history for multiple sold-out errors within a short period. This can mean that
2
the BIB connector or syrup pump has a suction leak. Fix if necessary.
3
Run the beater circuit diagnostic if a component failure is suspected.
Error #070: Compressor Ran Too Long
The compressor ran continuously for more than 90 minutes.
Is the location an extreme volume venue such as a festival? If so, contact FBD service for
1
instructions on adjusting the timer.
2
Run the refrigeration diagnostic sequence to determine the reason for the failure.
Error #081, 082, 083, 084: High Barrel Pressure
The pressure on a barrel exceeded 55 PSIG (379 kPag).
1
Dispense a drink to reduce the barrel pressure. The dispenser will refreeze if set to the ON mode.
2
Run the fill diagnostic if a failed component is suspected.
Check the "Active Charge" regulator located on the product header to ensure it is set at 30
PSIG (207 kPag). All barrels should be fully depressurized before checking the active charge.
3
On non-DCC dispensers, use a tire gauge to check the pressure.
On DCC dispensers, use the pressure displayed on the LCD Screen.
Error #090: Hot Product Detected
The system shut down because product in a barrel exceeds 90° F (32.2° C) for 200 seconds or 110° F (43.3° C) for 50
seconds depending on dispenser software.
1
Check the return temperature sensor for proper operation.
2
If hot product was detected, call FBD for technical assistance.
Error #111, 112, 113, 114: Motor Failure
The beater motor is not operating.
1
Run a beater circuit diagnostic to determine the problem or refer to error #58X in this manual.
2
Check to make sure the beater motor is plugged in.
42