M
PAXD - U
ODEL
PAXD SPECIFICATIONS
INPUT RANGES:
INPUT
ACCURACY*
RANGE
(18 to 28°C)
0.03% of reading
0.12% of reading
±200 µADC
+0.03 µA
0.03% of reading
0.12% of reading
±2 mADC
+0.3 µA
0.03% of reading
0.12% of reading
±20 mADC
+3µA
0.05% of reading
0.15% of reading
±200 mADC
+30 µA
0.5% of reading
0.7% of reading
±2 ADC
+0.3 mA
0.03% of reading
0.12% of reading
±200 mVDC
+30 µV
0.03% of reading
0.12% of reading
±2 VDC
+0.3 mV
0.03% of reading
0.12% of reading
±20 VDC
+3 mV
0.05% of reading
0.15% of reading
±300 VDC
+30 mV
0.05% of reading
0.2% of reading
100 ohm
+30 Mohm
0.05% of reading
0.2% of reading
1000 ohm
+0.3 ohm
0.05% of reading
0.2% of reading
10 Kohm
+1 ohm
M
PAXP - P
ODEL
PAXP SPECIFICATIONS
SENSOR INPUTS:
INPUT
ACCURACY*
ACCURACY*
(RANGE)
(18 to 28°C)
(0 to 50°C)
20 mA
0.03% of
0.12% of
reading +2 µA
reading +3 µA
(-2 to 26 mA)
10 VDC
0.03% of
0.12% of
(-1 to 13 VDC)
reading +2 mV
reading +3 mV
* After 20 minute warm-up. Accuracy is specified in two ways: Accuracy over an 18
to 28°C and 10 to 75% RH environment; and accuracy over a 0 to 50°C and 0 to
85%RH (non-condensing environment). Accuracy over the 0 to 50°C range
includes the temperature coefficient effect of the meter.
EXCITATION POWER:
Transmitter Power: 24 VDC, ±5%, regulated, 50 mA max.
NIVERSAL
ACCURACY*
IMPEDANCE/
CONTINUOUS
(0 to 50°C)
COMPLIANCE
OVERLOAD
1.11 Kohm
15 mA
+0.04µA
111 ohm
50 mA
+0.4 µA
11.1 ohm
150 mA
+4 µA
1.1 ohm
500 mA
+40 µA
0.1 ohm
+0.4 mA
1.066 Mohm
100 V
+40 µV
1.066 Mohm
300 V
+0.4 mV
1.066 Mohm
300 V
+4 mV
1.066 Mohm
300 V
+40 mV
0.175 V
30 V
+40 Mohm
1.75 V
30 V
+0.4 ohm
17.5 V
30 V
+1.5 ohm
ROCESS
MAX
IMPEDANCE/
CONTINUOUS
COMPLIANCE
OVERLOAD
20 ohm
150 mA
500 Kohm
300 V
DC I
! FOUR VOLTAGE RANGES (300 VDC Max)
! FIVE CURRENT RANGES (2A DC Max)
! THREE RESISTANCE RANGES (10K Ohm Max)
! SELECTABLE 24 V, 2 V, 1.75 mA EXCITATION
MAX
RESOLUTION
* After 20 minute warm-up. Accuracy is specified in two ways:
10 nA
Accuracy over an 18 to 28°C and 10 to 75% RH environment; and
0.1 µA
accuracy over a 0 to 50°C and 0 to 85% RH (non-condensing
environment). Accuracy over the 0 to 50°C range includes the
1 µA
temperature coefficient effect of the meter.
10 µA
EXCITATION POWER:
Transmitter Power: 24 VDC, ±5%, regulated, 50 mA max.
3 A
0.1 mA
Reference Voltage: 2 VDC, ± 2%
Compliance: 1 kohm load min. (2 mA max.)
10 µV
Temperature coefficient: 40 ppm/°C max.
Reference Current: 1.75 mADC, ± 2%
0.1 mV
Compliance: 10 kohm load max.
Temperature coefficient: 40 ppm/°C max.
1 mV
10 mV
0.01 ohm
0.1 ohm
1 ohm
I
NPUT
! DUAL RANGE INPUT (20 mA or 10 VDC)
! 24 VDC TRANSMITTER POWER
DISPLAY
RESOLUTION
1 µA
1 mV
4
NPUT