錯誤碼
異常現象說明
Error
Cause of the Problem
Code
Hall sensor 異常
Err 21

Hall Sensor Abnormal

安全開關檢知遮斷
Safety Switch Error
解決措施
Measurement and Solution
1. 關閉電源。
Turn off the power.
2. 檢查電機編碼器連接線(CN701)是否接觸不良或馬達編
碼器是否故障。
Check the connection between motor encoder and control
box or (CN701) if any malfunction on motor encoder board.
3. 排除後重新送電,若仍無法正常運轉,請通知廠商。
Turn on the power again. If the machine still cannot operate
normally, please contact with qualified technician.
一般模式下,旋轉符號不轉動時:
When the motor rotating symbol stops during Normal Mode:
1. 關閉電源,檢查縫紉機安全開關(CN706)是否故障。
Turn off the power and check the connection for safety
switch (CN706).
2. .排除後重新送電,若仍無法正常運轉,請通知廠商。
Turn on the power again. If the machine still cannot operate
normally, please contact with qualified technician.