Vermont Castings 2950 Installation And Operating Manual page 37

Pinnacle & stardance direct vent, rear vent gas heater
Table of Contents

Advertisement

Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
NOTE: Be sure burner leg remains at a 90° angle to
firebox base after conversion.
Models 2997, 2998 (RF Models) Only
16. Follow procedure for pilot type 2 to replace pilot
orifice.
17. Remove and replace plug on lower right hand side
of the valve; Red for LP and Blue for NG. (Fig. 65,
Page 32)
18. Remove motor top cap. Depress and turn center
plunger until arrow points to correct screw. Red for
LP and Blue for NG. NOTE: Plunger will "snap" into
NG position when arrow is close to blue screw. It will
not "snap" at LP (Red) position. (Fig. 75)
19. Insure manifold pressure remains between 3.2" -
3.5" w.c. for NG and 9.5" - 10" w.c. for LP. To adjust
the manifold pressure, for NG, using a torque #10 key
turn the blue screw clockwise to increase the manifold
pressure. Turn the screw counterclockwise to de-
crease the pressure. Use the red screw to adjust LP.
20. Replace motor top cap.
Center
Plunger
Blue - NG
Red - LP
Fig. 75 Depress and turn center plunger.
Kit #
000-5004
000-5013
000-5029*
Kit #
000-5005
000-5014
000-5030*
*Models 2950, 2951
20003457
Motor Top Cap
Valve
FP1037b
Table 2. Injector Orifice Size Matrix
Conversion to Natural Gas
Front
Part #
#56 / .0465"
30000336
#56 / .0465"
30000336
#56 / .0465"
3000-0336
Conversion to LP
Front
Part #
#68 / .031"
30000694
#68 / .031"
30000694
#67 / .032"
3000-0338
All Models
21.Replace burner. Slide the burner in at an angle with
left side lower than the right side. Slide the left side
onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angle to the base.
(Fig. 76) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.
22.Place conversion label on valve.
23.Reinstall the right and left log bracket assembly.
24.Reinstall the rear log bracket.
25.Replace logs.
25.Replace glass and stove front.
Conversion is complete.
90°
Fig. 76 Remove and replace injector orifices.
Rear
Part #
#47 / .078"
20003054
#47 / .078"
20003054
#50 / .070"
3000-0337
Rear
Part #
#56 / .0465"
30000336
#56 / .0465"
30000336
#61 / .039"
3000-0339
Left Burner Leg
Injector Orifices
Input (BTU/h)
Minimum
Maxi,mum
14,000
21,000
14,000
21,000
14,000
20,000
Input (BTU/h)
Minimum
Maximum
14,000
21,000
14,000
21,000
14,000
20,000
ST353a
37