Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
Comfort Valve System Control Sequence Of Operation With Transmitter
Local Path
If manual switch is
set to LOCAL, did
main burner light
and fan turn on?
Yes
Turn pilotstat knob
to PILOT to turn
off main burner.
Turn pilotstat knob
to OFF to turn
valve completely
off.
34
Set manual switch
to local or remote
Light pilot burner
No
Did the LED stop
blinking?
Release pilotstat
knob.
Yes
Turn pilotstat knob
from PILOT to ON.
Move switch from
local to remote.
Press any key on
transmitter. Move
switch back to
local.
Five minute wait
period
Review LED
failure analysis.
Cycle switch once
and leave in
remote. Press any
key on transmitter
for recognition
operation.
On Path
If the manual switch
is set to REMOTE,
press the mode
button to display
"ON".does transmit-
ter control the main
burner and fan?
Yes
Does transmitter
change levels of
flame height, fan
speed?
Yes
Set levels of flame
height and fan to
"0" to shut off main
burner and fan.
Turn pilotstat knob
to OFF to turn
valve completely
off.
Choose Manual or
Remote path. Set
switch to manual or
remote.
Move switch from
manual to remote.
Press any key on
transmitter.
No
20003457