Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
Transition
Connector
16"
(406mm)
Fig. 45 SDVR minimum lintel height for flush or forward placement.
Fireplace Installations Using Existing Wood Stove Chimneys
Existing Wood Stove
Chimney Pipe
Finished
Combustible Wall
20 "
(521mm)
* Transition pipe must be at least 6"
(152mm) from any combustible material.
Fig. 46 SDVR installations using existing wood stove chimney pipe.
24
Fireplace Installation Requirements - SDVR
26"
(660mm)
ST379a
*
6"
(152mm)
ST713a
Transition
Connector
20 "
(521mm)
Existing Vent Pipe
Field
Fabricated Cover
Transition Connector
"X" must be 6" (151mm) from any combustible material
unless completely covered by field fabricated sheet metal. If
3" vent pipes are covered by sheet metal, the clearance to
combustibles may be 2" (51mm).
26"
(660mm)
ST380a
X
ST714
20003457