Code
Name
0002
Hardware
Failure
0003
ROM
Checksum
Error
Description
General hardware
failure (unable to
localize failure to a
specific system)
Corrupted ROM
Action
Unplug the All-In-One;
wait a few seconds,
then plug the
All-In-One back in and
turn the power on. If
the error remains,
clean the NVRAM by
pressing the Up
Arrow button and
Menu button
simultaneously. The
Self Test menu
appears; select Clean
NVRAM. If the error
continues, replace the
system board.
Unplug the All-In-One;
wait a few seconds,
then plug the
All-In-One back in and
turn the power on. If
the error remains,
clean the NVRAM by
pressing the Up
Arrow button and
Menu button
simultaneously. The
Self Test menu
appears; select Clean
NVRAM. If the error
continues, replace the
system board.
Diagnostic information
4416-XXX