Automatic air-conditioning fan controller

Webasto
HG
F3
4
X1
rt
1
87
87a
86
K3
85
30
sw
5
15
IPCU
A
E
86
85
2
Webasto components
HG
Heater TT-C/E
X1
6-pin heater connector GR
F3
25 A fuse
K3
Fan relay
IPCU Pulse width modulator MF6
Y
Wiring adapter
IPCU adjustment values:
Duty cycle: 42%
Frequency: 1000Hz
Voltage:
5V
Function:
High-side
5
4
1314460B_EN
Citroen Berlingo / Peugeot Partner
rt
0,75²
Y
rt
sw
3
0,75²
rt
4
0,75²
Vehicle components
KB
A/C control unit
Fan relay
GM
Fan module
a
2-pin connector GM
Fuse
Ter. 15
Measure
(e.g., 16-pin OBD socket
outlet, Pin 1)
1
11
3
Citroen, Peugeot
GR
or
rt
rt
or
2
GM
2
ge/gr
0,5²
ge/gr
0,5²
Colours and symbols
rt
ws
sw
ge
gr
or
X
Wiring colours may vary.
Fan motor is controlled on 2-pin connector A 1
of fan module.
Produce connections as shown in wiring dia-
gram.
2 Orange (or) wire of connector A, Pin 2
3 Y-adapter
2
4 Black (sw) wire from K3/30
5 Orange (or) wire of GR
30
15
MF6
sw/ws
1
M
1
A
ws/
rt
10
4
KB
31
red
white
black
yellow
gray
orange
Cutting point