AEG DDLE LCD 18 Operating And Installation Instructions page 25

Electronically controlled comfort instantaneous water heater
Table of Contents

Advertisement

Available languages

Available languages

10.2 Alternative installation methods
10.2.1 Electrical connection from below on
unfinished walls
» Fit the cable grommet.
Material losses
!
If you break open the wrong knock-out in the back
panel by mistake, you must use a new back panel.
» Break out the cable grommet knock-out in the
back panel. Deburr any sharp edges with a file if
necessary.
» Reposition the mains terminal in the appliance from
the top to the bottom.
» Push the back panel over the threaded stud and the
cable grommet. Pull the cable grommet by the lock-
ing hooks into the back panel using pliers, until both
locking hooks audibly click into place.
» Press the back panel firmly into place and lock the
fixing toggle by turning it clockwise through 90°.
10.2.2 Electrical connection on finished walls
Note
This type of connection changes the IP rating of the
appliance.
» Change the type plate. Cross out "IP 25" and
mark the box "IP 24". Use a ballpoint pen to do
this.
Material losses
!
If you break open the wrong knock-out in the back
panel by mistake, you must use a new back panel.
» Cleanly cut or break out the required cable entries
in the back panel (for positions, see chapter "Speci-
fication / Dimensions and connections"). Deburr any
sharp edges with a file if necessary.
10.2.3 Connecting a load shedding relay
10.2.4 Undersink installation, water connections –
10.2.5 Water installation on finished walls
1
L1 í
2
» Route the power cable through the cable grommet
and connect it to the mains terminal.
Install a load shedding relay in the distribution board in
conjunction with other electric appliances, e.g. electric
storage heaters. The relay responds when the instanta-
neous water heater starts.
Material losses
!
Connect the phase that switches the load shedding
relay to the indicated terminal of the mains terminal
in the appliance (see chapter "Specification / Wiring
diagram").
from above
An undersink installation with water connections from
above can be achieved with the additional pipe assembly
for undersink appliances. Cleanly break out the water pipe
knock-outs in the back panel and fit the pipe assembly.
Note
This type of connection changes the IP rating of the
appliance.
» Change the type plate. Cross out "IP 25" and
mark the box "IP 24". Use a ballpoint pen to do
this.
» Fit water plugs with gaskets to seal the concealed
connections.
» Fit a suitable pressure tap.
» Click the lower section of the back panel into place in
the upper section of the back panel.
» Secure the connection pipes to the appliance.
» Secure the back panel at the bottom with two addi-
tional screws.
Material losses
!
If you break open the wrong knock-out in the back
panel by mistake, you must use a new back panel.
Installation
25

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ddle lcd 18/21/24Ddle lcd 27222392222394222395

Table of Contents