For H-754, H-755, H-756 & H-757 Low Profile Floor Scale
Your floor scale was shipped with the scale feet used as overload stops. The
feet on your scale are screwed up through the load cells against the deck plate to
protect the load cells during shipment.
Simply screw the feet down three turns by hand and level the scale by additional
adjusting of the feet. You should have firm contact on all four feet.
Plug the TI-500E instrument cable connector into the digital weight indicator.
This cable is located in the floor scale side access compartment. To access the
instrument cable with connector, remove the two screws from the side access cover
plate, and then remove the cover plate. You will find a heavy-duty red cable inside the
compartment. Route the cable from the inside, through the opening in the backside of
this compartment and out from under the scale to your digital weight indicator.
Note: Do not open the gray ABS Junction Box that is also located in this compartment.
Plug the 110V power plug from the digital weight indicator into a wall socket.
Turn the power switch on the backside of the digital weight indicator to the on position.
You are now ready to weigh. Reinstall the side access cover plate.
Do not calibrate the scale, it has been calibrated at the factory to meet or
exceed H-44 specifications.
CHICAGO
ATLANTA
ULINE
SHIPPING SUPPLY SPECIALISTS
FAX 1-800-295-5571
Set-up Instructions
DALLAS
MINNEAPOLIS
uline.com
LOS ANGELES
NYC/PHILA

Advertisement

loading

Summary of Contents for U-Line H-754

  • Page 1 Set-up Instructions For H-754, H-755, H-756 & H-757 Low Profile Floor Scale Your floor scale was shipped with the scale feet used as overload stops. The feet on your scale are screwed up through the load cells against the deck plate to protect the load cells during shipment.
  • Page 2 ULINE SHIPPING SUPPLY SPECIALISTS PHONE 1-800-295-5510 FAX 1-800-295-5571 uline.com Troubleshooting Information Should shipping screws be removed from the scale base before the scale is put into use? Yes. The shipping screws are put into place to protect the scale from damage during shipping.
  • Page 3 ULINE SHIPPING SUPPLY SPECIALISTS PHONE 1-800-295-5510 FAX 1-800-295-5571 uline.com ERROR MESSAGES: If the scale encounters an error, it will display a message alerting the operator. A description follows: Code Mode Meaning/Possible Solution Normal Operating Mode Gross Overload. A weight greater than the scale capacity has been put on the scale.
  • Page 4 ULINE SHIPPING SUPPLY SPECIALISTS PHONE 1-800-295-5510 FAX 1-800-295-5571 uline.com Parts List Description Qty. Rubber Boot for DC Power Jack Housing Screw Kit (12 Pcs) 2.5K Load Cell ABS-JBox Floor Scale Foot Mounting Hardware for L/C’s Side Cover Plastic Housing-Front Metal Housing- Rear Stainless Steel Housing Stainless Steel Rear Cover Stainless Stand –...

This manual is also suitable for:

H-755H-756H-757