32 x 12/14 bit 50/75 msps adc for mtca.4 rear-i/o (95 pages)
Summary of Contents for Tews Technologies TPMC316
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 2
The Embedded I/O Company TPMC316 Conduction Cooled CAN Bus PMC Module Version 1.2 User Manual Issue 1.2.1 August 2014 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101 4058 0 Fax: +49 (0) 4101 4058 19 e-mail: info@tews.com www.tews.com...
Page 3
RS485 interface reserves the right to change the product described in this document at any time without notice. TEWS TECHNOLOGIES GmbH is not liable for any damage arising out of the application or use of the device described herein.
Page 4
New address TEWS LLC September 2006 (1) New Notation for User Manual and Engineering Documentation 1.0.5 February 2010 (2) Added Note for TPMC316-10 Min. Baud Rate in the Technical Specification Table 1.1.0 New hardware version with new CAN controller October 2011 1.2.0...
RS485 interface for each of the two channels. The bus line termination can be enabled or disabled for each channel by solder pads (disabled per default). The TPMC316 has no front panel. It uses P14 I/O connector with the same pin assignment as the TPMC816.
On board 120 ohms, disabled per default Transfer Rate Up to 1 Mbps at bus line length of up to 40 m Minimum Baud Rate for the TPMC316-10R is 60 Kbps (TJA1050 CAN Transceiver Timeout Feature) Isolation CAN bus isolated by optocouplers and DC/DC converter for each...
Table 3-1 : PCI9030 Local Space Configuration Local Address Space 0 The complete register sets of the two CAN controllers of the TPMC316 are accessible in the memory space of the PMC module. Address range: PCI Base Address 2 for Local Address Space 0 + (0x0000 to 0x00FF)
PCI9030 Local Space 1 Not used 0x30 Expansion ROM Not used Table 4-2 : PCI9030 Base Address Usage TPMC316 User Manual Issue 1.2.1 Page 13 of 20 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
0x74 Hidden 2 Power Management data 0x00000000 Not used scale Table 4-3 : PCI9030 Local Configuration Register TPMC316 User Manual Issue 1.2.1 Page 14 of 20 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
PCI9030 remains in this reset condition until the PCI Host clears this bit. The contents of the PCI9030 PCI and Local Configuration Registers are not reset. The PCI9030 PCI Interface is not reset. TPMC316 User Manual Issue 1.2.1 Page 16 of 20...
D[7..0] 8 Bit lower lane Byte 0 D[7..0] Table 5-2 : Local Bus Little/Big Endian Standard use of the TPMC316: Local Address Space 0 16 bit bus in Little Endian Mode Local Address Space 1 not used Local Address Space 2...
Page 19
Expansion ROM Bus Region Description Register You could also use the PCI - Base Address 1 I/O Mapped Configuration Registers. TPMC316 User Manual Issue 1.2.1 Page 18 of 20 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
CAN bus channel 1 active. Figure 6-1 : Soldering Connection Location LB1 – LB2 Physical Interface The TPMC316-10R provides a CAN High Speed interface and the TPMC316-11R a modified RS485 interface. TPMC316 User Manual Issue 1.2.1 Page 19 of 20 Artisan Technology Group - Quality Instrumentation ...
High level CAN voltage input/output channel 1 CAN High Speed or modified RS485 Ground channel 1 16…32 Table 7-1 : Mezzanine P14 Connector TPMC316 User Manual Issue 1.2.1 Page 20 of 20 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 22
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the TPMC316 and is the answer not in the manual?
Questions and answers