Jøtul F 55 V2 Carrabasset - Jøtul F 602 CB V2 Installation Planning Manual

Table of Contents

Advertisement

Jøtul F 55 V2 Carrabassett
Heat Output Range:
Heating Capacity:
Maximum Burn Time:
3
EPA Efficiency:
4
CO Emissions:
Pariculate Emissions:
Fuel Length:
Weight:
Bottom Heat Shield included
Optional Accessories
• Stove Gloves #157363
• Stove Top Thermometer #5002
• Outside Air Kit #158208
• Mobile Home Bracket Kit
#157321
• Blower Kit #156431
• Short Leg Kit #158209
Hearth Protection
Any floor that is not composed of
concrete poured on earth requires
protection from sparks and
embers. The Jøtul F 55 Carrabassett
approved for installation using one
of the following forms of hearth
protection:
• Any UL, ULC, or Warnock Hersey
Listed Type 1 hearth board.
Any noncombustible material.
• Hearth protection must extend 8"
from the sides and back and 16"
from the front door opening (18
1/8'' in Canada)
• In a rear vent installation, floor
protection must also extend under
the stove pipe a minimum of 2"
beyond either side. See figure 71.
40 3/4"
40 3/4”
*50 1/2"
Figure 71. Minimum Hearth Dimensions.
* Denotes requirement for Canada.
1
Heat Output Range results are determined during specific emissions tests established by the EPA.
2
Heating Capacity and Maximum Burn Time will vary depending on design of home, climate, wood type and operation
3
EPA Validated Efficiency:
High Heat Value and Low Heat Value efficiencies are determined per the CSA B415.1-10 test method. The difference between the
HHV and LHV is in how the energy in the exhaust gas water vapor is accounted.
LHV efficiency assumes all the water vapor in combustion gas was condensed and the heat from such was recovered and
transferred to the dwelling. HHV calculations do not assume all water vapor is condensed, therefore the HHV value is less than
the LHV value.
16
Carbon Monoxide Emissions rate results from Test Method CSA B415.1-10.
4
Particulate Emissions rate is obtained using EPA Test Methods: ALT-125 (Cordwood Fuel), ASTM E2515-11, ASTM E3053-17
5.
1
18,962 to 84,311 BTU/hr.
2
Up to 2,300 sq. ft.
2
Up to 10 hours
HHV: 67.97% LHV: 73.13%
1.06 g/min.
5
1.31 g/hr
Up to 18" Logs (Front to Back)
475 lbs
2”
2"
2”
22 3/4”
16”
16"
DOOR
OPENING
*18"
33"
8"
8”
8”
8"
*43 1/2"
33”
27 5/8"
27 5/8”
(702 mm)
17 3/8"
17 3/8”
(440 mm)
Figure 72. F 55 Carrabassett dimensions. See clearance
chart for flue collar centerline positions.
Fireplace Clearances
A: Stove to Mantel, max. depth 12":
35"
B: Floor to Mantel: 66"
C: Stove to Top Trim, 1" thick or less:
31"
D: Stove to Side Trim, 1" thick or less:
14"
Alcove Installation
Requirements
• Chimney connection requires
listed double-wall pipe.
• Optional Bottom Heat Shield must
be installed.
• UL/ULC or WH listed hearth pad or
a noncombustible material having
a minimum R value of 0.5.
• Min. Ceiling Clearance from hearth
Fig. 76.
A: Unprotected: 72"
Protected:
• Wall and ceiling protection, if
used, must extend over the entire
area.
18"
2"
*8"
A
48"
Figure 76. Alcove Ceiling and Double-wall
Connector Clearances.
30 5/8"
30 5/8”
15 1/2" x 10 1/2"
(778 mm)
15 1/2” x 10 1/2”
30 5/8"
30 5/8”
Viewing Area
(779 mm)
A
C
B
Figure 73. Mantel & Trim Clearances.
A: Unit to Mantel (12 in. deep)- 35 in. / 89 cm
B: Floor to Mantel-
C: Stove to 1 in. Top Trim -
D: Stove to 1 in. Side Trim -
16”
16"
(406 mm)
59 1/2"
59 1/2”
(1511 mm)
Figure 74. Alcove with no wall protection.
59"
6"
6”
(152 mm)
39 1/2"
39 1/2”
(1003 mm)
Figure 75. Alcove with wall protection.
48"
27 1/4"
27 1/4”
(692 mm)
Viewing Area
7 1/2"
7 1/2”
(190 mm)
C
D
66 in. / 168 cm
31 in. / 79 cm
14 in. / 36 cm
19"
19”
(483 mm)
Maximum
Maximum
48”
48"
(1219 mm)
16"
16”
(406 mm)
8"
8” (203 mm)
Maximum
Maximum
48”
48"
(1219 mm)
6”
6"
(152 mm)